Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
Error code Description Action
BA04000F Self test failed on device; no error or
location code information available
1. If a location code is identified with the
error, replace the device specified by the
location code.
2. If the problem persists:
a. Go to “Checkout procedure” on page
184.
b. Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA040010 Self test failed on device; can't locate
package.
1. If a location code is identified with the
error, replace the device specified by the
location code.
2. If the problem persists:
a. Go to “Checkout procedure” on page
184.
b. Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA040020 The machine type and model are not
recognized by the blade server
firmware.
1. Reboot the blade server.
2. If the problem persists:
a. Go to “Checkout procedure” on page
184.
b. Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA040030 The firmware was not able to build the
UID properly for this system. As a
result, problems may occur with the
licensing of the AIX operating system.
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA040035 The firmware was unable to find the
“plant of manufacture” in the VPD. This
may cause problems with the licensing
of the AIX operating system.
Verify that the machine type, model, and serial
number are correct for this server. If this is a
new server, check for server firmware updates;
then, install the updates if available.
BA040040 Setting the machine type, model, and
serial number failed.
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA040050 The h-call to switch off the boot
watchdog timer failed.
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
60 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)