Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
Error code Description Action
BA060070 The operating system does not support
this system's processor(s)
Boot a supported version of the operating
system.
BA060071 An invalid number of vectors was
received from the operating system
Boot a supported version of the operating
system.
BA060072 Client-arch-support hcall error
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA060075 Client-arch-support firmware error
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA060200 Failed to set the operating system boot
list from the management module boot
list
1. Using the SMS menus, set the boot list to
the default boot list.
2. Shut down; then, start up the blade server.
3. Use SMS menus to customize the boot list
as required.
4. If the problem persists:
a. Go to “Checkout procedure” on page
184.
b. Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA060201 Failed to read the VPD "boot path" field
value
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA060202 Failed to update the VPD with the new
"boot path" field value
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA060300 An I/O error on the adapter from which
the boot was attempted prevented the
operating system from being booted.
1. Using the SMS menus, select another
adapter from which to boot the operating
system, and reboot the system.
2. Attempt to reboot the system.
3. Go to “Boot problem resolution” on page
190.
BA07xxxx self configuring SCSI device (SCSD)
controller failure
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
Chapter 2. Diagnostics 63