Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
Error code Description Action
BA140002 The SCSD read/write optical test unit
ready failed; sense data available.
1. Troubleshoot the SCSD devices.
2. Verify that the SCSD cables and devices are
properly plugged. Correct any problems
that are found.
3. Replace the SCSD cables and devices.
4. If the problem persists:
a. Go to “Checkout procedure” on page
184.
b. Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA140003 The SCSD read/write optical send
diagnostic failed; sense data available.
1. Troubleshoot the SCSD devices.
2. Verify that the SCSD cables and devices are
properly plugged. Correct any problems
that are found.
3. Replace the SCSD cables and devices.
4. If the problem persists:
a. Go to “Checkout procedure” on page
184.
b. Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA140004 The SCSD read/write optical send
diagnostic failed; devofl command.
1. Troubleshoot the SCSD devices.
2. Verify that the SCSD cables and devices are
properly plugged. Correct any problems
that are found.
3. Replace the SCSD cables and devices.
4. If the problem persists:
a. Go to “Checkout procedure” on page
184.
b. Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA150001 PCI Ethernet BNC/RJ-45 or PCI
Ethernet AUI/RJ-45 adapter: internal
wrap test failure
Replace the adapter specified by the location
code.
BA151001 10/100 Mbps Ethernet PCI adapter:
internal wrap test failure
Replace the adapter specified by the location
code.
BA151002 10/100 Mbps Ethernet card failure
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA153002 Gigabit Ethernet adapter failure Verify that the MAC address programmed in
the FLASH/EEPROM is correct.
70 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)