Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
Error code Description Action
BA180012 PCI device runtime error, bridge in
freeze state
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA180014 MSI software error
1. Reboot the blade server.
2. If the problem persists:
a. Go to “Checkout procedure” on page
184.
b. Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA180020 No response was received from a slot
during PCI probing.
1. Reboot the blade server.
2. If the problem persists:
a. Go to “Checkout procedure” on page
184.
b. Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA180099 PCI probe error; bridge in freeze state,
slot in reset state
1. Reseat the PCI adapter card.
2. Check for adapter firmware updates; then,
install the updates if available.
3. Check for server firmware updates; then,
install the updates if available.
4. Replace the PCI adapter card.
5. If the problem persists:
a. Go to “Checkout procedure” on page
184.
b. Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA180100 The FDDI adapter Fcode driver is not
supported on this server.
IBM may produce a compatible driver in the
future, but does not guarantee one.
BA180101 Stack underflow from fibre-channel
adapter
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA190001 Firmware function to get/set
time-of-day reported an error
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
74 Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)