EasyManua.ls Logo

IBM Power PS700 - Page 91

IBM Power PS700
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
Error code Description Action
BA278007 Failed to reboot the system after a
firmware flash update
Restart the blade server.
BA278009 The operating system's server firmware
update management tools are
incompatible with this system.
Go to the IBM download site at
www14.software.ibm.com/webapp/set2/sas/
f/lopdiags/home.html to download the latest
version of the service aids package for Linux.
BA27800A The firmware installation failed due to a
hardware error that was reported.
1. Look for hardware errors in the event log.
2. Resolve any hardware errors that are found.
3. If the problem persists:
a. Go to “Checkout procedure” on page
184.
b. Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA280000 RTAS discovered an invalid operation
that may cause a hardware error
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA290000 RTAS discovered an internal stack
overflow
1. Go to “Checkout procedure” on page 184.
2. Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA290001 RTAS low memory corruption was
detected
1. Reboot the blade server.
2. If the problem persists:
a. Go to “Checkout procedure” on page
184.
b. Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA290002 RTAS low memory corruption was
detected
1. Reboot the blade server.
2. If the problem persists:
a. Go to “Checkout procedure” on page
184.
b. Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA310010 Unable to obtain the SRC history
1. Reboot the blade server.
2. If the problem persists:
a. Go to “Checkout procedure” on page
184.
b. Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
Chapter 2. Diagnostics 79

Table of Contents

Other manuals for IBM Power PS700

Related product manuals