Table 3-2 (Page 6 of 9). Firmware Error Codes.
Error Code Description Action/
Possible Failing FRU
xxx=000 Initialization failed, device test failed
001 init-nvram invoked, ALL of NVRAM
initialized
002 init-nvram invoked, GE area preserved,
remaining areas initialized.
011 Data corruption detected, ALL of
NVRAM initialized
012 Data corruption detected, GE area
preserved, remaining areas initialized
100 NVRAM data validation check failed. Turn off, turn on system unit and retry
the operation.
25AA0xxx EEPROM Note: Ensure that the EEPROM
Security jumper is in the correct
position if doing a
priviliged-access password
install.
Consult the system's User's Guide for
jumper location and position.
Retry the operation.
If retries do not solve the problem,
replace the system board.
xxx=000 Unable to unlock EEPROM
001 Read-Recv error
002 Read-Trans error
003 Write-enable error
004 Write-recv error
005 Write-disable error
006 Write-Trans error
007 Unable to lock EEPROM
25Cyyxxx Memory
Chapter 3. Error Code to FRU Index for Model 140 and Model 240 3-9