Table 4. Abbreviated list of POST error codes (continued)
v Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v See the parts listing in the Problem Determination and Service Guide to determine
which components are customer replaceable units (CRU) and which components
are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must
be performed only by a trained service technician.
Error code Description Action
175 Service processor flash code
damaged or not loaded.
Note: In this case, the service
processor is the optional Remote
Supervisor Adapter II SlimLine.
1. Update the Remote Supervisor
Adapter II SlimLine firmware
(see the Problem
Determination and Service
Guide on the IBM System x
Documentation CD).
2. Replace the Remote
Supervisor Adapter II SlimLine.
184 Power-on password damaged.
1. Run the Configuration/Setup
Utility program, select Load
Default Settings, and save the
settings.
2. Reseat the battery.
3. Replace the following
components one at a time, in
the order shown, restarting the
server each time:
a. Battery
b. (Trained service technician
only) System board
187 VPD serial number not set.
1. Set the serial number by
updating the BIOS code level
(see the Problem
Determination and Service
Guide on the IBM System x
Documentation CD).
2. (Trained service technician
only) Replace the system
board.
189 Three attempts were made to
access the server with an incorrect
password.
Restart the server and enter the
administrator password; then, run
the Configuration/Setup Utility
program and change the power-on
password.
289 A DIMM has been disabled by the
system.
1. Make sure that the DIMM is
installed correctly (see
“Installing a memory module”
on page 13).
2. Replace the DIMM.
3. (Trained service technician
only) Replace the system
board.
50 System x3200 Type 4362 and 4363: Installation Guide