Table 4. Abbreviated list of POST error codes (continued)
v Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v See the parts listing in the Problem Determination and Service Guide to determine
which components are customer replaceable units (CRU) and which components
are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must
be performed only by a trained service technician.
Error code Description Action
1162 Serial port error
1. Run the Configuration/Setup
Utility program and make sure
that the serial port settings are
correct.
2. (Trained service technician
only) Replace the system
board.
178x Fixed disk error.
Note: x is the drive that has the
error.
1. Run the hard disk drive
diagnostic tests on drive x (see
“Running the diagnostic
programs” in the Problem
Determination and Service
Guide on the IBM System x
Documentation CD).
2. Reseat the following
components, depending on the
server model:
v Hot-swap models: Hard disk
drive
v Simple-swap models:
a. Hard disk drive x
b. Hard disk drive x cable
3.
Replace the following
components one at a time,
depending on the server
model, in the order shown,
restarting the server each time:
v Hot-swap models:
a. Hard disk drive x
b. Hard disk drive
backplane
v
Simple-swap models:
a. Hard disk drive x
b. Hard disk drive x cable
4.
(Trained service technician
only) Replace the system
board.
52 System x3200 Type 4362 and 4363: Installation Guide