Table 4. Abbreviated list of POST error codes (continued)
v Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v See the parts listing in the Problem Determination and Service Guide to determine
which components are customer replaceable units (CRU) and which components
are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must
be performed only by a trained service technician.
Error code Description Action
1803 No more memory (above 1 MB for
a PCI adapter).
1. If the error code indicates a
particular PCI or PCI-E slot or
device, remove that device.
2. If the error remains, reseat the
each adapter.
3. Replace the following
components one at a time, in
the order shown, restarting the
server each time:
a. Failing PCI adapter
b. (Trained service technician
only) System board
1804 No more memory (below 1 MB for
a PCI adapter).
1. Remove the failing adapter.
2. Reseat each adapter
3. Replace the following
components one at a time, in
the order shown, restarting the
server each time:
a. Failing PCI adapter
b. (Trained service technician
only) System board
1805 PCI option ROM checksum error.
1. Remove the failing adapter.
2. Reseat each adapter
3. Replace the following
components one at a time, in
the order shown, restarting the
server each time:
a. Failing PCI adapter
b. (Trained service technician
only) System board
54 System x3200 Type 4362 and 4363: Installation Guide