IBM System x3500 - Replacing the Fan Cage Assembly

IBM System x3500
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. Reconnect the cables and power cords (see “Connecting the cables” on page
114).
5. Update the server configuration (see “Updating the server configuration” on
page 115).
6. Install the server in the rack cabinet (see the Tower to Rack Installation
Instructions that come with the server for instructions).
7. Slide the server back into the rack, if necessary.
8. Start the server. Confirm that it starts correctly and recognizes the newly
installed devices, and make sure that no error LEDs are lit.
9. (IBM Business Partners only) Complete the additional steps in “Instructions for
IBM Business Partners” on page 29.
Replacing the fan cage assembly
To replace the fan cage assembly, complete the following steps.
Attention: Make sure that all wires and cables inside the server are routed
correctly before you install the fan cage assembly. Wiring that is not properly routed
might be damaged or might prevent the fan cage assembly from seating properly in
the server.
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 37.
2. Align the guides on the fan cage with the release latch to the open position on
each side.
3. Push the fan cage assembly into the server.
Note: Make sure that the fan cage is fully seated.
4. Rotate the fan cage release latch to the close position. The fan cage will be fully
seated when it is secured.
110 IBM System x3500 M4 Type 7383: Installation and User’s Guide