EasyManuals Logo
Home>IBM>Server>System x3650 M4 Type 7915

IBM System x3650 M4 Type 7915 User Manual

IBM System x3650 M4 Type 7915
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #139 background imageLoading...
Page #139 background image
Statement 34:
CAUTION:
To reduce the risk of electric shock or energy hazards:
v This equipment must be installed by trained service personnel in a
restricted-access location, as defined by the NEC and IEC 60950-1, First
Edition, The Standard for Safety of Information Technology Equipment.
v Connect the equipment to a properly grounded safety extra low voltage
(SELV) source. A SELV source is a secondary circuit that is designed so
that normal and single fault conditions do not cause the voltages to exceed
a safe level (60 V direct current).
v Incorporate a readily available approved and rated disconnect device in the
field wiring.
v See the specifications in the product documentation for the required
circuit-breaker rating for branch circuit overcurrent protection.
v Use copper wire conductors only. See the specifications in the product
documentation for the required wire size.
v See the specifications in the product documentation for the required torque
values for the wiring-terminal screws.
Important: Be sure to read the multilingual safety instructions on the CD that
comes with the server before you use the product.
Chapter 2. Installing optional devices 121

Table of Contents

Other manuals for IBM System x3650 M4 Type 7915

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 M4 Type 7915 and is the answer not in the manual?

IBM System x3650 M4 Type 7915 Specifications

General IconGeneral
BrandIBM
ModelSystem x3650 M4 Type 7915
CategoryServer
LanguageEnglish

Related product manuals