BASIC OPERATION
3
Display backlighting
The transceiver has display backlight for night-time operation.
q Push and hold [Top]
(Set Mode) for 2 sec. to enter set
mode.
w Push [Top]* several times until LIGHT appears.
e Push [CH Up] or [CH Down] to select the display back-
light condition.
ON : Backlight lights continuously.
A2 : Lights for 5 sec. when any key except [PTT] is pushed, or
the LCD indication is changed.
AT : Lights for 5 sec. when any key except [PTT] is pushed or
the Selcall signal is transmitted/received.
OF : Backlight never lights.
r Rotate [VOL] to turn the power OFF, or push and hold
[Top]
(Set Mode) for 2 sec. to exit set mode.
*Regardless of the assigned key function.
Set mode
Set mode is accessed at power ON and allows you to set sel-
dom-changed settings. In this case you can customize the
transceiver operation to suit your preferences and operating
style. See p. 34 for set mode items detail.
Entering the set mode:
q While pushing and holding [CH Up] and [CH Down],
rotate [VOL] to turn the power ON. Then, push and hold
[Top]
(Set Mode) for 2 sec. to enter set mode.
w Push [Top]* several times to select the appropriate item.
Then push [CH Up] or [CH Down] to set the desired level/
condition.
Available set mode functions are SQL Level, CTCSS tone/
DTCS code, Auto power OFF, Backlight, Beep, Beep Level,
Mic Gain, Battery Voltage, Signal Moni, Power Save, TOT,
Lock-out, Scan Stop Timer, Scan Restart, Roger Beep and
Own ID.
e Rotate [VOL] to turn the power OFF, or push and hold
[Top]
(Set Mode) for 2 sec. to exit set mode.
NOTE: Set mode can be accessed via the [Top]
(Set Mode)
key operation only (p. 34.) In this case, set mode allows
quicker item selection. Set Enable to the most often used
items with the CS-41S
CLONING SOFTWARE
.
*Regardless of the assigned key function.
[

Table of Contents