60
8
SET MODE
Power save (P SAVE)
The power save function reduces the current drain to con-
serve battery power. This item sets the power save duty
cycle—the ratio of receive circuit on to receive circuit off while
standing by. The duty cycle can be set to automatic (default),
1:1, 1:4, 1:8, 1:16 or OFF.
“AUTO” selects “1:4” duty ratio when receiving no signal for 5
sec., then “1:8” 60 sec. after that.
When “AUTO” is selected, the power save automatically
turns OFF while operating with an external DC power.
(10–11.5 V DC)
For packet operation, the power save should be turned
OFF to receive reliable packet data.
Monitor switch action (MONI)
The monitor switch can be set as a ‘sticky’ switch. When set
to the sticky condition, each push of [SQL] toggles the moni-
tor function on and off.
PUSH Set the monitor switch to
normal. (default)
HOLD Set the monitor switch to
sticky switch.
Dial speed acceleration (SPEED)
The dial speed acceleration automatically speeds up the tun-
ing dial speed when rotating the [DIAL] rapidly.
•ON The dial speed acceleration
is turned ON. (default)
OFF The dial speed acceleration
is turned OFF.
ii
SET MODE

Table of Contents

Other manuals for Icom IC-E90

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-E90 and is the answer not in the manual?

Icom IC-E90 Specifications

General IconGeneral
BrandIcom
ModelIC-E90
CategoryTransceiver
LanguageEnglish

Related product manuals