89
11 SCAN OPERATION
New2001
■ Scan resume condition
[
The scan resume condition can be selected as timer or pause
scan. The selected resume condition is also used for priority
watch. (pgs. 86, 87)
DD
Setting from the application
qDisplay the Set Mode screen.
- Select “Edit Set Mode(C
)...” in View menu.
- Click “” in tool bar.
- Press [F7] key on the PC keyboard.
wDouble click the “Scan Resume Timer” cell, then select the
desired scan resume condition from “P-2,” “T-5,” “T-10” and
“T-15.”
• Resuming conditions
•“P-2” : Scan pauses until the signal disappears and then re-
sumes 2 sec. later.
•“T-5” : Scan pauses 5 sec. while receiving a signal.
•“T10” : Scan pauses 10 sec. while receiving a signal.
•“T-15” : Scan pauses 15 sec. while receiving a signal.
eTo close the Set Mode screen, click “” in tool bar or click
“
.
”
DD
Setting from the RC-24
qPush [TXinh• ] for 0.5 sec. to enter set mode.
wPush [MODE] or [TXinh• ] several times to select “Scan
Timer” item.
• Select “ON” for “Extension” item in advance.
eRotate [DIAL] to select the desired scan resume condition.
• See “•Resuming conditions” above.
rPush [PWR] momentarily to exit set mode.
Scan
Timer
T-10
[MODE]
[TXinh• ]
Double click
then select the desired
scan resume condition.
ID-1_ENG_2.qxd 04.9.22 9:30 Page 89 (1,1)