ELECTRIC BICYCLE METER KTLCD7C Product User Manual
- 27 -
press button (UP) or button (DOWN) for selection.
C10 parameter definition table
C10 value
Restore default setting
n
Function off
y
Function on
When the meter is needed to restore default setting, C10 selects y, hold button
for about 2 seconds, all parameters restore default settings and exit setting environment,
and then return to the display1.
C10 selects n, press button (SW) to save the current set values and enter C11
parameter setting interface.
C11 Meter Attribute Selection Setting
Enter C11 parameter setting interface, C11 parameter column flashes.
C11 parameter setting interface
C11 is meter attribute selection setting, the setting range is 0-2, press button
(UP) or button (DOWN) for selection.
C11 parameter definition table
C11
value
Meter Attribute
0
Meter uses LCD10YN new version of communication protocol, it is
compatible LCD1 and LCD2.
1
Meter uses LCD1 and LCD2 old version communication protocol, it is not
compatible second display.