104 iDirect Satellite Router Installation and Commissioning Guide
iDX Release 3.3
Setting Power
8. Click OK to save the changes.
9. Right-click the remote in
the iBuilder Tree and select Apply ConfigurationReliable Both
(TCP).
Note: In iBuilder, separate Max Power and Init
ial Power values can be configured for
multiple SCPC upstream carriers per remote to facilitate switching the remote
from one SCPC return channel to another. If the remote will be transmitting
more than one SCPC return channel, repeat the previous procedure for each
SCPC carrier. The Initial Power may vary per carrier depending on a number of
factors, including satellite transponder response, symbol rate, MODCOD, and
block size.
After completion of the procedures
in this chapter
, continue to “Post Acquisition Activities”
on page105.