8.2 Switching
8.2.1 Restricting the Automatic Switching with activated MSC
Keyboard command Function
Hot Key, x, m, Enter
With activated MSC restrict the automatic switching and enable the manual
mode. The mouse cannot be moved over the edge of a screen.
Hot Key, x, a, Enter
With activated MSC enable the automatic MSC function. The mouse can be
moved over the edge of a screen.
8.2.2 Activate/Deactivate Switching via Mouse
Keyboard Command Mode Activate/deactivate switching via mouse
Hot Key, o, x, 0,
Enter
Mode 0 Deactivate switching via mouse, mouse in absolute mode
Hot Key, o, x, 1,
Enter
Mode 1 Activate the horizontal mode 4x1
Hot Key, o, x, 2,
Enter
Mode 2 Activate the vertical mode 1x4
Hot Key, o, x, 3,
Enter
Mode 3 Activate the block mode 2x2
Hot Key, o, x, 4,
Enter
Mode 4 Activate the free mode, individual layout, mouse in absolute
mode
8.2.3 Switching the USB-HID Control
Keyboard command Switching function
Hot Key, Num0
Switch the USB-HID control to the own display (CON Unit with keyboard and
mouse)
Hot Key, Num1
Switch the USB-HID control to display 1
Hot Key, Num2
Switch the USB-HID control to display 2
Hot Key, Num3
Switch the USB-HID control to display 3
Hot Key, Num4
Switch the USB-HID control to display 4
8.2.4 Deactivating and Reactivating unused or non-connected Ports
Keyboard Command
Mode
Hot Key, x, d, Enter
Deactivate unused or non-connected ports
Hot Key, x, e, Enter
Reactivate unused or non-connected ports
Hot Key, x, c, Enter
Reactivate all unused or non-connected ports