termination of NiMH and NiCd battery. The effective
value ranges from 5 to 20mV per cell. If the trigger
voltage is set higher, there is a danger of
overcharging the battery; if it is set lower, there is a
possibility of premature termination. Please refer
the technical specification of the battery. (NiCd
default: 12mV, NiMH default: 7mV)
An optional feature using temperature probe
contacting the surface of battery, the temperature
cut-off can be on or off. If it is on, set the maximum
temperature at which the charger should allow
battery to reach during charge. Once a battery
reaches this temperature during charge, the
process will be terminated to protect the battery.
The battery is on the cyclic process of charge and
discharge can often become warm after charge or
discharge period. The program can insert a time
delay to occur after each charge and discharge
process to allow the battery adequate time to cool
down before being subjected to the next process.
The value ranges from 1 to 60 minutes.
You can set the trickle charge mode on or off. If it is
on, the charger will automatically supply the trickle
charge current to achieve the full charge without
overheating the battery after fast charge has been
terminated.
When you start a charge process, the integral safety
timer automatically starts running at the same time.
This is programmed to prevent overcharge the
battery if it proves to be faulty, or if the termination
circuit cannot detect the battery full. The value for
the safety timer should be generous enough to allow
a full charge of the battery.