149CS-7008-FD, CL-7016-FD analog inputs
Current measurement with shunt plug
Parameter
Value typ.
min. / max.
Remarks
Input range
±50 mA, ±20 mA, ±10 mA, ±5 mA,
±2 mA, ±1 mA
Shunt impedance
50 Ω
external plug ACC/DSUBM-I2
Over load protection
±
60 mA
permanent
Input configuration
differential
Gain error
0.02%
0.06%
0.1%
of the reading, at 25°C
additional error of 50 Ω in plug
Gain drift
15 ppm/K
×D
T
a
55 ppm/K
×D
T
a
D
T
a
=|T
a
-25°C| ambient temperature T
a
Offset error
0.02%
0.05%
of the range, at 25°C
Noise
40 nA
rms
0.7 nA
rms
0.17 nA
rms
70 nA
rms
12 nA
rms
0.3 nA
rms
Bandwidth:
0.1 Hz to 50 kHz
0.1 Hz to 1 kHz
0.1 Hz to 10 Hz
Current measurement with internal shunt
Parameter
Value typ.
min. / max.
Remarks
Input range
±
50 mA,
±
20 mA,
±
10 mA,
±
5 mA,
±
2 mA,
±
1 mA
Shunt impedance
120
W
internal
Over load protection
±
60 mA
permanent
Input configuration
Single-ended
internal current sink to -VB
Gain error
0.02%
0.06%
of the reading, at 25°C
Gain drift
15 ppm/K
×D
T
a
55 ppm/K
×D
T
a
D
T
a
=|T
a
-25°C| ambient temperature T
a
Offset error
0.02%
0.05%
of the range, at 25°C
Noise
40 nA
rms
0.7 nA
rms
0.17 nA
rms
70 nA
rms
12 nA
rms
0.3 nA
rms
Bandwidth:
0.1 Hz to 50 kHz
0.1 Hz to 1 kHz
0.1 Hz to 10 Hz