19
INSTALLER
USER
MAINTENANCE TECHNICIAN
TECHNICAL DATA
Mounting the horizontal intake-exhaust kit Ø80/125 (Fig.
13).
To install the kit Ø80/125 one must use the anged adapter kit
in order to install the ue system Ø80/125.
Install the bend with ange (2) onto the central hole of the boiler
inserting the gasket (1) and tighten using the screws included in
the kit.
Fit the male end (smooth) of the adapter (3) up to the end stop
on the female side of the bend (2) (with lip seal).
Fit the Ø 80/125 (4) concentric terminal pipe with the male end
(smooth) to the female end of the adapter (3) (with lip gasket)
up to the end stop; making sure that the internal and external
wall sealing plates have been tted; this will ensure sealing and
joining of the elements making up the kit.
Extensions for Ø 80/125 horizontal kit (Fig. 14).
e kit with this conguration can be extended up to a maximum
length of 7.3 m, including the terminal with grid and excluding
the concentric bend leaving the boiler and the adapter Ø 60/100
in Ø 80/125. is conguration corresponds to a resistance factor
of 100. In this case the special extensions must be requested.
1.12 CONCENTRIC VERTICAL KIT INSTALLATION.
Type C conguration, sealed chamber and fan assisted.
Concentric vertical intake and exhaust kit. is vertical terminal
is connected directly to the outside of the building for air intake
and ue gas exhaust.
N.B.: the vertical kit with aluminium tile enables installation on
terraces and roofs with a maximum slope of 45% (approx 25°)
and the height between the terminal cap and half-shell (374 mm
for Ø 60/100 and 260 mm for Ø 80/125) must always be observed.
Mounting the vertical kit with aluminium tile Ø60/100
(Fig. 15).
To use this kit one must use the xing plate kit 60/100 (sold
separately).
Install the concentric ange (2) on the central hole of the boiler
inserting the gasket (1) and tighten using the screws in the kit. Fit
the male end (smooth) of the adapter (3) into the female end of
the concentric ange (2). Imitation aluminium tile installation.
Replace the tile with the aluminium sheet (5), shaping it to ensure
that rainwater runs o. Position the xed half-shell (7) and insert
the intake-exhaust pipe (6). Fit the Ø 80/125 concentric terminal
pipe with the male end (6) (smooth) to the female end of the
adapter (3) (with lip gasket) up to the end stop; making sure that
the wall sealing plate (4) has been tted, this will ensure sealing
and joining of the elements making up the kit.
Extensions for vertical kit Ø 60/100 (Fig. 16).
e kit with this conguration can be extended to a max. straight
vertical length of 4.7 m, including the terminal. is congura-
tion corresponds to a resistance factor of 100. In this case specic
extensions must be requested.