2.6 INFORMATION MENU.
Pressing the buttons (3) and (4) simultaneously for 3 seconds,
the “Information menu” is activated, which displays some boiler
functioning parameters.
Press buttons (3) and (4) to scroll through the various parameters.
To exit the menu, press buttons (3) and (4) simultaneously again
for 3 seconds or wait for 5 minutes.
Id Parameter Description
d1 Displays the ame signal
d2 Displays the primary exchanger output instant ow temperature (ow probe)
d3 Displays the instant output temperature from the DHW exchanger (DHW probe)
d4 Not used
d5 Displays the operating instantaneous power (value in %).
d6 Displays the actual temperature for the central heating set (if remote control is present)
d7 Displays the temperature set for the DHW set (if remote control is present)
E1 - E7 Display the anomaly history, of which E1 is the most recent
2.7 RESETTING THE ANOMALY HISTORY.
Press the “ ” button on the information menu for > 2 seconds
and < 5 seconds.
e display will show "E-": at this point release the " " key.