48
4.3 TECHNICAL DATA.
- e data relevant to domestic hot water performance refers to a
dynamic inlet pressure of 2 bar and an inlet temperature of 15°C;
the values are measured directly at the boiler outlet considering
that to obtain the data declared mixing with cold water is neces-
sary.
- e max. sound level emitted during boiler operation is < 55dBA.
e sound level value is referred to semianechoic chamber tests
with boiler operating at max. heat output, with extension of ue
gas exhaust system according to product standards.
- * Eciencies refer to the net caloric value.
- e weighted NOx value refer to the net caloric value.
Domestic hot water nominal heat input kW 25.5
Central heating nominal heat input kW 25.5
Minimum DHW heat input kW 7.6
Minimum heat input kW 12.8
Domestic hot water nominal heat output (useful) kW 23.5
Central heating nominal heat output (useful) kW 23.5
DHW minimum heat output (useful) kW 6.7
Minimum heat output (useful) kW 11.3
*Eciency at nominal heat output (80/60°) % 92.3
*Eciency at 30% nominal heat output load % 89.2
Heat loss at case with burner On/O W 248 / 116
Heat loss at ue with burner On/O W 1564 / 7
Central heating circuit max. operating pressure bar 3
Maximum central heating temperature °C 90
Adjustable central heating temperature °C 35-80
System expansion vessel total volume l 4.2
Heating expansion vessel pre-charge bar 1.0
Appliance water content l 0.7
Head available with 1000 l/h ow rate kPa 30.4
Domestic hot water adjustable temperature °C 35 - 55
Domestic hot water circuit min. pressure (dynamic) bar 0.3
Domestic hot water circuit max. operating pressure bar 10
Minimum D.H.W. ow rate l/min 1.7
Flow rate capacity in continuous duty (∆T 30°C) l/min 11.2
Weight of full boiler kg 29.7
Weight of empty boiler kg 29.0
Electrical connection
V~/Hz
230/50
Nominal power absorption A 0.63
Installed electric power W 130
Pump absorbed power W --
Fan power absorbed power W 39
Equipment electrical system protection - IPX5D
Ambient operating temperature range °C 0.5 ÷ 40
Maximum ue overheating temperature °C 180
NO
X
class - 2
Weighted NO
X
mg/kWh 159.8
Weighted CO mg/kWh 62
Tipo apparecchio B22 / B22p / B32 / C12 / C32 / C42 / C52 / C62 / C82
Categoria II2H3P