EasyManua.ls Logo

Immergas EOLO STAR 24 4E - Page 44

Immergas EOLO STAR 24 4E
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44
INSTALLER
USER
MAINTENANCE TECHNICIAN
TECHNICAL DATA
P12
Maximum hea-
ting setting
Denes the maximum ow temperature 35 - 80 °C 80°C
P13
Temperature
gradient
Change the insucient circulation intervention value (E27)
00 - 15
(0 = Function
deactivated)
11
P14
Pump functio-
ning
e pump can function in two ways:
oF intermittent: in "winter" mode, the circulator is managed by the room
thermostat or by the remote control.
on continuous: in "winter" mode the circulator is always powered and is
therefore always in operation.
oF - on oF
P15
Gas valve
calibration
Not used on this model. - - - - - -
P16 Valve check Not used on this model. - - - - - -
P17 Solar delay
e boiler is set to switch-on immediately aer a request for DHW. In the
case of coupling with a solar storage tank positioned upstream from the
boiler, it is possible to compensate the distance between the storage tank
and the boiler in order to allow the water to reach the boiler. Set the time
necessary to verify that the water is hot enough not to start the boiler.
00 - 60
(00 = Function
deactivated)
01 - 60 seconds
00
P18 Display lighting
Establishes the display lighting mode:
00 = (O) the display lights on if buttons are pressed (time out = 15 secon-
ds).
01 = (Auto) equal to 00, it also lights on to indicate the ame presence.
02 = (On) always on.
00 - 02 01
P19
Flow o tempe-
rature increase
(Central heating)
Increases the ow o temperature at ignition only in the rst 30 seconds. on - oF on

Table of Contents

Related product manuals