IDS440 Users Manual version 4.2 Set Operation Parameters
29
Parameter 9. Push Button Zero Percent (100)
Enter the percent of full-scale capacity that can be acquired as the zero point with the
ZERO key. 1 = 1%, 2 = 2%, ... 100 = 100%.
Parameter 10. Primary Units Type (1 [lb])
The scale is calibrated in the primary units. The UNITS key is used to toggle the weight
display between primary units and alternate units. Enter the number that corresponds
with the primary units:
0 = UNDEFINED, no units printed
1 = lb
2 = kg
3 = ton
4 = ten
5 = gram
6 = oz
7 = use print label 32 for units
8 = use print code 1 for units
NOTE: when parameter 10 is changed, parameters 13 and 16 must be programmed.
Parameter 11. Decimal Point Position (0 [no decimal point])
Enter the decimal point position for the primary units display. For example, if the scale is
calibrated x 0.05 the decimal position = 2.
Parameter 12. Count-by (1)
Enter the primary units count-by. For example, if the scale is configured for:
x 0.05 count-by = 5
x 0.2 count-by = 2
x 1 count-by = 1
x 5 count-by = 5
x 50 count-by = 50
Note: the entry for 0.05 and 5 is the same. The decimal point position (parameter 11)
differentiates between the count-by 0.05 and count-by 5.