IDS440 Users Manual version 4.2
62
Sample Cable Drawings
Load Cell
IDS150A/152/160/320
L
O
AD
C
ELL
N
ote: connect sheild to the enclosure connector hood
1
2
3
4
5
6
7
S
i
g
n
a
l +
S
i
g
n
a
l -
Ex
c
i
tat
i
o
n +
Se
n
se
+
n
-
Ex
c
i
tat
i
o
n -
Shield
TB 3
DB 25 PIN MALE
(RS232)
TB1
Serial Com Port 1
TXD
GN
D
C
T
S
2
5
7
3
7
4
RXD
GN
D
RT
S
ID
S
1
50
A
/
1
5
2
/
1
60/3
2
0
DB 25 PIN MALE
(
20ma Current Loo
p)
TB1
Serial Com Port 1
+5R
CL1 TX
4
622
CL+
CL-
IDS150A/152/160/320
8