IDS440 Users Manual version 4.2 Parameter Functions
49
Function 71 Configure Event Monitor
Use function 71 to enter setpoint data into the Event Monitor. See the “Scale Basic /
Event Monitor” manual” for more information on the event monitor parameters.
1. Hold the CLEAR key down and press the ENTER key to enter the configure mode.
2. Enter CFG 71. The IDS440 prompts “Eno”. Enter the Event number to be modified.
3. The IDS440 prompts “P0 xx” where P0 is parameter 0 and xx is the current value of
parameter 0. Enter new data for P0 or press the ENTER key to use the displayed
data.
4. Use the UNITS key (↓) or the PRINT key (↑) to scroll through the parameter
numbers. Press the CLEAR key to exit from the current Event number. Press the
CLEAR key again to exit from event monitor data entry.
Function 72 Scale Basic Function Editor
Use function 72 to create or modify Scale Basic functions. See the “Scale Basic / Event
Monitor” manual for more information on Scale Basic functions.
1. Hold the CLEAR key down and press the ENTER key to enter the configure mode.
2. Enter CFG 72. The IDS440 prompts “Fn”. Enter the function number to be
modified.
3. The IDS440 prompts “0- xxx” where 0- is entry zero, and xxx is the current value for
entry zero. Enter new data for 0- or press the ENTER key to use the displayed data.
4. Use the UNITS key (↓) or the PRINT key (↑) to scroll through the entry numbers.
Press the CLEAR key to exit from the Function Editor.
Function 73 Initialize Function Memory
The initialize function erases function memory and setpoint monitor memory, and
initializes all parameters with password level 1 or 2.
Function 73 prompts “rs Fn” . Press the Enter key to initialize only or enter a number
below to activate a built in program.
1. Fill to Setpoint.
2. Checkweigh: Over/Between/Under
3. Weigh-in / Weigh-out
4. Axle Weigh – Short Scale
5. Axle Weigh – Long Scale
6. ID Tare and Total
7. Peak Hold