Appendix II 47
Unknown Fiber Type
Dust on the ber surface. Re-prepare the ber.
Different ber types on two sides.
AUTO mode is not applicable in
this case; select a suitable splice
mode to redo splicing.
The ber is a non-standard ber.
AUTO mode can only detect
standard SM, MM, NZ bers.
Fiber Clad Over Limit
Fiber edge is not located in the
camera range.
Adjust the ber position; perform
[Motor Calibration].
Focus Motor Home
position Error
Shock occurred to the splicer
during the splicing process.
Perform [Motor Calibration]. If
the problem still exists, please
contact the sales agent.
Fiber Endface Gap Wrong
[Overlap] is too much. Adjust [Overlap] parameter.
Motor is not calibrated. Perform [Motor calibration].
Focus Motor Distance
Over Limit
The ber is misplaced. Press RESET button and
reposition the ber correctly.
Dust or dirt on the ber surface. Prepare the ber again.
Dust or dirt on the lenses.
Perform [Dust Check] after the
lenses are cleaned.
Fibers Mismatch,
Continue?
Different ber types on two sides.
It may result in large splice loss
if you continue to splice. Please
use the proper splice mode
corresponding to the bers.
Cleave Angle Over Limit
Bad ber endface.
Check the condition of the ber
cleaver. If the blade is worn,
rotate the blade to a new position
or change a new one, and then
re-prepare the bers.
[Cleave Angle Limit] is set too low.
Increase the [Cleave Angle Limit]
to an adequate limit (standard:
3.0˚).
Core Angle Over Limit
[Core Angle Limit] is set too low. Increase the [Core Angle Limit] to
an adequate limit (standard: 1.0˚).
Dust or dirt on the V-groove or
ber holders.
Clean the V-groove and ber
holders. Prepare the bers and
re-load them.

Table of Contents