5 Create and download project
15
3.2 Display parameters
Parameter type
Parameter description
Start page
Used to define the page displayed after power-on, generally used to
display the welcome page.
Default page
Used to set the default display page. When the ESC button has no
special function, press the ESC button to jump to the default page.
Alarm page
After defining this page, once there is an alarm message, it will
automatically jump to this page. Related to the alarm list, the alarm list
definition variable will jump to this page when an alarm occurs. If the
alarm page has been edited, it will jump to this page when an alarm
occurs. If the alarm page is 65535, jumps to the default alarm page when
an alarm occurs.
Note: If the set alarm page has not been edited, it will also jump to the
default alarm page when an alarm occurs.
Password level
This software defines the highest level 4 password.
Screen saver
It is used to set the time of no key operation and the screen saver page.
After this time, it will automatically jump to the screen saver page.
Turn off the
backlight
It is used to turn off the LCD backlight after the time of no key operation.
Auto alarm page
Used to define whether to jump to the alarm page when an alarm sign
appears. For the definition of alarm sign, see "3.1 Parameter Setting-
".
1) Page control
The page control function is to associate the interface number of the text with the data register of
the PLC. If you need this function, you first need to check the relevant options of status control,
and then set the D component address related to the text. Take D0 as the associated variable as
an example, as shown in the figure below:
2) Multi-language support
At present, the H0U integrated programmable controller only supports two languages, Chinese
and English. Set the switch between Chinese and English by storing language register under
parameter setting. When the storage language register is set to 0 text, the content of Language 1
When the D0 component
data of the PLC changes, the
page of the text also changes
to the page indicated by D0.
When the text page changes,
the D1 element of the PLC
will be converted into page
number data accordingly

Other manuals for Inovance H0U Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance H0U Series and is the answer not in the manual?

Inovance H0U Series Specifications

General IconGeneral
BrandInovance
ModelH0U Series
CategoryController
LanguageEnglish

Related product manuals