Chapter 3 Servo Pump Trial Run Steps and
Prototyping of Servo Pump Optional Parts
3.1 Servo Pump Trial run Process
3.2 Motor Trail Run
3.2.1 Set motor parameters of group F1˄F1-00 to F1-05ˈF1-15˅
3.2.2 Set pole-pairs number of the rotary encoder
3.2.3 Set the drive to non-oil pressure control mode˖A3-00 ˙“0”
3.2.4 Set the drive to operation panel control mode, at this time the light of
LOCAL/REMOT is off.
3.2.5 Motor parameter tuning( automatic identification) ˄F1-16˅
Servo driver
commissioning
Set the relevant parameters correctly
Motor parameter tuning
*Motor commissioning, adjust parameters
of the speed and current loop
Oil pressure control mode setup
Motor parameter( F1)
Control parameter
( A3-00? F0- 02)
Motor
commis
sioning
*AI zero drift automatic correction
*Function parameter setup
*Injection molding machine commissioning,
adjust pressure loop parameter
Servo
pump
applicati
on
Finish
Motor parameter tuning
( F1-16)
Motor response parameter
(F2)
Oil pressure control mode
(A3-00)
AI zero drift auto correction
(A3-20)
Flow and oil pressure
command( A3-01? 02? 03)
Pressure relief( A3-08)
Minimum flow( A3-09)
Minimum pressure( A3-10)
Oil pressure PID( A3)
Note: ( 1) Detailed instructions please refer to the following corresponding contents.
( 2) Do not conduct the commissioning steps with *, it can also start the injection molding machine action.