Function
Code
Function Code
Description
Setup
F0-03 Frequency source
If A3-00˙“2”, F0-03˙“3 ”(A I2 is
frequency source).If A3-00˙ “1”
or “3”, F0-03˙“9”(Communication
setup is frequency source)
F0-07
Frequency source
selection
0 (Non-auxiliary frequency
source)
F0-17 Speed-up time 0.0s
F0-18 Speed-down time 0.0s
F1-00
Motor type
selection
2 (Synchronous motor)
F4-00
DI1 terminal
function selection
11˄Running enabled˅
F4-01
DI2 terminal
function selection
48 (Oil pressure control PID
select terminal 1)
F4-02
DI3 input function
selection
49(Oil pressure control PID select
terminal 2)
F4-03
DI4 input function
selection
9 (Fault reset)
F4-04
DI5 input function
selection
50(CAN communication enabled)
F5-01
DO1 output
function selection
2 (Fault output)
F5-02
DO2 output
function selection
23(Double-displacement plunger
pump swash plate switch˄NO˅
F5-03 DO3 output
function selection
24 (Pressure control status output
NC)
It may be power-failure recorded (the drive restore to be the setup
value automatically while power-on again) when modify the above
parameters in the oil pressure control mode, When the oil pressure
mode switches to the non-oil pressure mode, the above parameters
will be restored to switch to the numerical value which is before oil
pressure control mode.
3.3.4 Command setup of flow and oil pressure˄A3-01ǃA3-02ǃ
A3-03˅:
a)A3-01˖ Maximum rotation speed. Set the motor running maximum