Chapter 10 Appendix IS580 User Manual
- 130 -
Note
•
For detailed wiring and CAN communication wiring, refer to the foldouts at the end of this chapter.
•
For the parameter setting, refer to the following related parameter setting part.
•
You can ensure the same motor speed through the communication.
The following gure shows the multi-pump distributed ow structure chart.
Figure B-2 The multi-pump distributed ow structure chart
M
M
M
Master drive
Pressure
reference 1
Flow
reference 1
Pressure
feedback 1
Pressure sensor 1
Pump
#1
Pump
#2
Pump
#3
Slave drive
Slave drive
CAN bus
Oil inlet
Oil outlet 1
Pressure
reference 2
Flow
reference 2
Pressure
feedback 2
Pressure
reference 3
Flow
reference 3
Pressure
feedback 3
Pressure sensor 2 Pressure sensor 3
Oil outlet 2
Oil outlet 3
① ② ③
④
Note
•
For detailed wiring and CAN communication wiring, refer to the foldouts at the end of this chapter.
•
For the parameter setting, refer to the following related parameter setting part.
•
You can ensure the same motor speed through the communication.
•
The convergent ow and distributed ow of pump 2 and pump 3 can be controlled by energizing solenoid
valves
. In the convergent ow control, the pressure reference, ow reference
and pressure feedback signal received by the drive are invalid. In the distributed ow control, the CAN
communication command received by the drive are invliad.