Chapter 3 Mechanical and Electrical Installation IS580 User Manual
- 34 -
3.8 Use of the Operation Panel
The IS580 has a built-in LED operation panel. An external LED operation panel can also be connected to the RJ45
interface of the IS580 by an 8-core at cable.
You can modify the parameters, monitor the working status and start or stop the IS580 by operating the operation
panel, as shown in the following gure.
Figure 3-22 Diagram of the operation panel
MF.K
RUN
STOP
RES
QUICK
PRG ENTER
RUN
LOCAL/REMOT FED/REV TUNE/TC
RPM
%
A VHz
Command source
indicator
ON: terminal control
OFF: operation panel control
RUN indicator
Data display
Programming key
Menu key
RUN key
Forward/Reverse
rotation indicator
ON: reverse rotation
OFF: forward rotation
Tuning/Torque
control/Fault indicator
Unit indicator
Reserved
Stop/Reset key
Shift key
Increment key
Decrement key
Confirm key
3.8.1 Description of Indicators
RUN
ON indicates that the servo drive is in the running state, and OFF indicates that the servo drive is in the stop
state.
LOCAL/REMOT
It indicates whether the servo drive is operated by means of operation panel, terminal or communication
(remote).
LOCAL/REMOT: OFF Operation panel control
LOCAL/REMOT: ON Terminal control
LOCAL/REMOT: blinking Communication control