In this wiring method, the braking unit is connected to COM on one side and DIx on the other side. The function
code setting is as follows when the braking unit is connected to different DI terminals:
DI1: F4-00 = 11; DI2: F4-01 = 11; DI3: F4-02 = 11; DI4: F4-03 = 11; DI5: F4-04 = 11
2. Pay much attention to the power and heat dissipation conditions of the braking resistor. If Err15 is reported,
immediately cut off the power supply of the main circuit. Otherwise, a re may result.
3.7 Wiring Diagram of System Application
For wiring diagram of system application, see the foldout at the end of this chapter.