EasyManua.ls Logo

Inovance IS580 Series - Page 22

Inovance IS580 Series
151 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IS580 User Manual Chapter 3 Mechanical and Electrical Installation
- 21 -
The IS580 series servo drive dissipates heat from the bottom to the top. The drive of IS580T080-R1-H-1 to
IS580T210-R1-H-1dissipates heat from the left to the right. When multiple servo drives are required to work
together, install them side by side.
For the application of installing multiple servo drives, if one row of Servo drives need to be installed above another
row, install an insulation guide plate to prevent servo drives in the lower row from heating those in the upper row
and causing faults.
Figure 3-2 Installation of the insulation guide plate
Insulation
guide plate
IS
580
IS580
3.1.3 Installation Method and Process
The IS580 series has two housing types, plastic housing and sheet metal housing, according to different power
classes. The IS580 supports both surface mounting and embedded mounting.
1. Surface mounting of the IS580 of plastic housing (IS580T020-R1-1 to IS580T070-R1-1)
Figure 3-3 Surface mounting of the IS580 of plastic housing
Install the servo drive from the
front of the control cabinet.
Back panel of the
control cabinet

Table of Contents

Other manuals for Inovance IS580 Series

Related product manuals