IS580 User Manual Chapter 3 Mechanical and Electrical Installation
- 41 -
3.8. 6 Starting or Stopping the Servo Drive
Selecting the Start/Stop Command Source
There are three start/stop command sources, namely, operation panel control, terminal control, and communication
control. You can select the command source in F0-02.
Function Code Parameter Name Setting Range Description Default
F0-02
Command source
selection
0: Operation panel
control (indicator OFF)
1: Terminal control
(indicator ON)
2: Communication
control (indicator
blinking)
0: Press
RUN
or
STOP
RES
to start or stop
the servo drive.
1: A DI terminal needs to be dened as the
run/stop terminal.
2: The communication protocol (Modbus-
RTU or CAN bus) is used.
0
0: Operation panel control
After you press
RUN
, the servo drive starts running (the RUN indicator is ON). After you press
STOP
RES
when
the servo drive is in running state, the servo drive stops running (the RUN indicator is OFF).
Note that the following operations can be performed only on the operation panel:
-
Motor auto-tuning
-
AI zero drift auto correction
1: Terminal control
This control mode is applicable to scenarios where the DIP switch or electromagnetic button is used to start or
stop the application system or scenarios where the dry contact signal is used to start or stop the servo drive.
The input terminals of the start/stop signal are set in F4-00 to F4-04.
Example:
To use the DIP switch as the start/stop source, and allocate the forward rotation switch signal to DI1 and the
reverse rotation switch signal to DI2, perform the setting as shown in the following gure.
Figure 3-31 Setting of using the DIP switch for start/stop
F4-00
1
2
.
.
F0-02 = 1
Running
command
F4-11 = 0
Control switch
Terminal
Function
code
Setting
value
Terminal
control
DI1
DI2
DI3
DI4
DI5
COM
Forward RUN
Forward RUN
Terminal control
Command source
selection
Two-line mode 1
Reverse RUN
Reverse RUN
SW2
SW1
F4-01
F4-02
F4-03
F4-04
In the oil pressure mode, DI1 with function 1 (Forward RUN) is used to enable the pump.