Chapter 7 Selection IS580 User Manual
- 86 -
Table 7-3 Cable dimensions and tightening torque of IS580T050/070
Servo drive Model Rated Input
Current (A)
Recommended Cable
Diameter (mm
2
)
Tightening Torque
(N·m)
Recommended
Cable Lug Model
IS580T050-R1-1 57 16 4.0 GTNR16-6
IS580T070-R1-1 69 25 4.0 GTNR25-6
Figure 7-6 Terminal dimensions of IS580T080/100
MOTOR POWER
24.826.8
R S T
BR (+) (-)
U
V
W
31
111
11
M8 flat washer +
spring washer + nut
M8
Combination
screw
Table 7-4 Cable dimensions and tightening torque of IS580T080/100
Servo drive Model Rated Input
Current (A)
Recommended Cable
Diameter (mm2)
Tightening Torque
(N·m)
Recommended
Cable Lug Model
IS580T080-R1-1 89 25 10.5 GTNR25-8
IS580T080-R1-H-1
IS580T100-R1-1 106 35
10.5 GTNR35-8
IS580T100-R1-H-1
Figure 7-7 Terminal dimensions of IS580T140/170/210
280
35
27
30.6
148.5
M12
bolt spring flat washer
R S
T
U V
W
POWER MOTOR
BR (+) (-)