MD021 Plastic Wire Drawing Machine User Manual
Display
Fault Name
Troubleshooting
proper range.
4. Check whether sudden load
occurs during deceleration. If yes,
eliminate sudden load.
Err04
Over-current
during
constant-speed
operation
1. Check whether the output
circuit of the inverter is
short-circuited. If yes, rectify the
fault.
2. Check whether sudden load
occurs during the running. If yes,
eliminate sudden load.
3. Check whether the load can be
reduced. If yes, reduce the load.
Err05
Over-voltage
during
acceleration
1. Check whether the input
voltage is too high. If yes, reduce
the voltage to the proper range.
2. Check whether the acceleration
time is too short. If yes, increase
the acceleration time.
Err06
Over-voltage
during
1. Check whether the input
voltage is too high. If yes, reduce

Related product manuals