MD021 Plastic Wire Drawing Machine User Manual
Display
Fault Name
Troubleshooting
deceleration
the voltage to the proper range.
2. Check whether the deceleration
time is too short. If yes, increase
the deceleration time.
Err07
Over-voltage
during
constant-speed
operation
Check whether the input voltage
is too high. If yes, reduce the
voltage to the proper range.
Err09
Under-voltage
fault
1. Check whether instantaneous
power failure occurs.
2. Check whether the input
voltage is too low. If yes, increase
the voltage to the proper range.
Err13
EEPROM
storage fault
Replace the operation panel or
drive board and then check
whether the fault is rectified.
Err14
Heatsink
overheat fault
1. Check whether the ambient
temperature is too high. If yes,
reduce the ambient temperature.
2. Check whether the air
ventilation channel is blocked. If
yes, clear the air ventilation