MD280 User Manual Troubleshooting
- 159 -
Overvoltage
during
acceleration
Err05
1. The input voltage is too high.
$QH[WHUQDOIRUFHGULYHVWKH
motor during acceleration.
3. The acceleration time is too
short.
4. The braking unit and braking
resistor are not installed.
1. Adjust the voltage to normal
range.
&DQFHOWKHH[WHUQDOIRUFHRU
install a braking resistor.
3. Increase the acceleration
time.
4. Install the braking unit and
braking resistor.
Overvoltage
during
deceleration
Err06
1. The input voltage is too high.
$QH[WHUQDOIRUFHGULYHVWKH
motor during deceleration.
3. The deceleration time is too
short.
4. The braking unit and braking
resistor are not installed.
1. Adjust the voltage to normal
range.
&DQFHOWKHH[WHUQDOIRUFHRU
install the braking resistor.
3. Increase the deceleration
time.
4. Install the braking unit and
braking resistor.
Overvoltage at
constant speed
Err07
1. The input voltage is too high.
$QH[WHUQDOIRUFHGULYHVWKH
motor during deceleration.
1. Adjust the voltage to normal
range.
&DQFHOWKHH[WHUQDOIRUFHRU
install the braking resistor.
Control power
supply fault
Err08
1. The input voltage is not within
the allowable range.
2. The input voltage is not
stable, causing the bus voltage
to jump frequently around the
undervoltage threshold.
1. Adjust the input voltage to
the allowable range.
:DLWDWOHDVW¿YHPLQXWHV
after power failure until the
input voltage becomes normal,
and then power on the AC
drive again.
Undervoltage Err09
1. Instantaneous power failure
occurs on the input power supply.
2. The AC drive's input voltage is
not within the allowable range.
3. The bus voltage is abnormal.
7KHUHFWL¿HUEULGJHDQGEXIIHU
resistor are faulty.
5. The drive board is faulty
6. The main control board is
faulty.
1. Reset the fault.
2. Adjust the voltage to normal
range.
3. Contact the agent or
Inovance.
AC drive
overload
Err10
1. The load is too heavy or
locked-rotor occurs on the motor.
2. The AC drive model is of too
small power class.
1. Reduce the load and check
the motor and mechanical
conditions.
2. Select an AC drive of higher
power class.
efesotomasyon.com