MD280 User Manual Product Information
- 27 -
2.8.1 Calculating the Resistance
The motor and load’s regenerative energy is almost consumed on the braking resistor when
braking.
$FFRUGLQJWRWKHIRUPXOD8[85 3E
U refers to the braking voltage at system stable braking.
The value of U varies with different systems. For 380V AC systems, U is generally
assigned a value of 700V.
Pb refers to the braking power.
2.8.2 Calculating the Power of Braking Resistor
In theory, the power of the braking resistor is consistent with the braking power. Considering
de-rating use to 70%, you can calculate the power of the braking resistor according to the
IRUPXOD[3U 3E['
Pr refers to the power of resistor.
'UHIHUVWRWKHEUDNLQJIUHTXHQF\SHUFHQWDJHRIWKHUHJHQHUDWLYHSURFHVVWRWKHZKROH
ZRUNLQJSURFHVV
Application Elevator
Winding and
unwinding
Centrifuge
Occasional
braking load
General
Application
Braking
Frequency
20%–
30%
20%–30% 50%–60% 5% 10%
Table 2-7 Recommended values of braking resistor
AC Drive Model
Recommended
Power
Recommended
Resistance
Braking
Unit
Remarks
MD280NS0.4GB 80 W ȍ
Built-in
VWDQGDUG
-
MD280NS0.7GB 80 W ȍ
MD280NS1.5GB 100 W ȍ
MD280NS2.2GB 100 W ȍ
MD280NT0.7GB 150 W ȍ
MD280NT1.5GB 150 W ȍ
MD280NT2.2GB 250 W ȍ
MD280NT3.7GB/5.5PB 300 W ȍ
MD280NT5.5GB/7.5PB 400 W ȍ
MD280NT7.5GB/11PB 500 W ȍ
MD280NT11GB/15PB 800 W ȍ
MD280NT15GB/18.5PB 1000 W ȍ
MD280NT18.5G/22P 1300 W ȍ
Built-in
RSWLRQDO
"B" added to the
AC drive model
MD280NT22G/30P 1500 W ȍ
MD280NT30G/37P 2500 W ȍ
efesotomasyon.com