Mechanical and Electrical Installation MD280 User Manual
- 44 -
Figure 3-23 Terminal layout of MD280NT110G/132P to MD280NT400G/450P
POWER
RST
- P
UVW
MOTOR
MD280
Model
0D[LPXP&DEOH6L]HRI3RZHU
7HUPLQDOPP
2
$:*NFPLO
Torque of the Torque
'ULYHU.JIÂFP
T110G/132P 150 300 98±5
T132G/160P 150 300 98±5
T160G/200P 150 300 98±5
T200G/220P 360 750 245±10
T220G/250P 360 750 245±10
T250G/280P 360 750 245±10
T280G/315P 360 750 245±10
T315G/355P 360 750 245±10
3.2.5 Description of Main Circuit Terminals
Ƶ
Safety Information
DANGER
Peform wiring only after all power supply is cut off. Failure to comply will result in electric
shock.
2QO\TXDOL¿HGSHUVRQQDODUHDOORZHGWRSHUIRUPZLULQJ)DLOXUHWRFRPSO\ZLOOUHVXOWLQ
equipment damage or personal injury.
7KHGHYLFHPXVWEHUHOLDEO\JURXQHG2WKHUZLVHLWZLOOFDXVHHOHFWULFVKRFNRU¿UH