F1-02
Rated motor
current
0.1–6553.5 A 0.1 A
Model
dependent
ƾ
F1-03
Rated motor
frequency
0.00 Hz to
PD[LPXPIUHTXHQF\)
0.01 Hz
Model
dependent
ƾ
F1-04 V/F curve setting
0: Linear V/F
1: Multi-point V/F
2: Square V/F
10
ƾ
F1-05 Torque boost
0.0%–30.0%
)L[HG
0.1%
Model
dependent
ƿ
F1-06
Cut-off frequency
of torque boost
+]WRPD[LPXP
IUHTXHQF\)
0.01 Hz 50.00 Hz
ƾ
F1-07
Multi-point V/F
IUHTXHQF\I
0.00 Hz to F1-09 0.01 Hz 0.00 Hz
ƾ
F1-08
Multi-point V/F
YROWDJHY
0.0%–100.0% 0.1% 0.0%
ƾ
F1-09
Multi-point V/F
IUHTXHQF\I
F1-07 to F1-11 0.01 Hz 0.00 Hz
ƾ
F1-10
Multi-point V/F
YROWDJHY
0.0%–100.0% 0.1% 0.0%
ƾ
F1-11
Multi-point V/F
IUHTXHQF\I
F1-09 to F1-03 0.01 Hz 0.00 Hz
ƾ
F1-12
Multi-point V/F
YROWDJHY
0.0%–100.0% 0.1% 0.0%
ƾ
F1-13
Slip compensation
FRHI¿FLHQW
0%–200.0% 0.1% 0.0%
ƿ
F1-14
2YHUH[FLWDWLRQ
gain
0–200 1 64
ƿ
F1-15 No-load current 0.1 A to F1-02 0.1 A
Model
dependent
ƿ
F1-16 Stator resistance ± ȍ
Model
dependent
ƿ
F1-17
Oscillation
suppression gain
0–100 1
Model
dependent
ƿ
F1-18
Auto-tuning
selection
0: No auto-tuning
1: Static auto-tuning
10
ƾ
F1-19
Oscillation
suppression mode
0–4 1 1
ƿ