Function Code Table
MD280 User Manual
- 86 -
Function
Code
Parameter Name Setting Range
Min.
Unit
Default
Property
F5-12
Accumulative
running time
threshold
0–65535 h 1 h 0 h
ƿ
F5-13
Action when set
accumulative
power-on time
reached
0: Continue to run
1: Stop
10
ƿ
F5-14 Startup protection
0: Disabled
1: Enabled
10
ƿ
F5-15
Frequency
detection value
+]WRPD[LPXP
IUHTXHQF\)
0.01 Hz 50.00 Hz
ƿ
F5-16
Frequency
detection
hysteresis
±)'7OHYHO 0.1% 5.0%
ƿ
F5-17
Detection range of
frequency reached
0.00–100% 0.1% 0.0%
ƿ
F5-18 Random PWM gain
0: Random PWM invalid
1–10
10
ƿ
F5-19
PWM modulation
mode
0: Asynchronous modulation
1: Synchronous modulation
10
ƾ
F5-20 Rapid current limit
0: Disabled
1: Enabled
11
ƾ
F5-21 Wakeup frequency F5-23 to F0-04 0.01 Hz 0.00 Hz
ƿ
F5-22 Wakeup delay time 0.0–6500.0s 0.1s 0.0s
ƿ
F5-23 Dormant frequency 0.00 Hz to F5-21 0.01 Hz 0.00 Hz
ƿ
F5-24 Dormant delay time 0.0–6500.0s 0.1s 0.0s
ƿ
F5-25
Software
overcurrent
threshold
±UDWHGPRWRU
FXUUHQW
0.1% 200.0%
ƿ
F5-26
Software
overcurrent
detection delay
VQRGHWHFWLRQ
0.01–6500.0s
0.01s 0.00s
ƿ
F5-27
Overcurrent
GHWHFWLRQGHOD\IRU
'2RXWSXW
VQRGHWHFWLRQ
0.01–6500.0s
0.01s 0.00s
ƿ
F5-37
Dead zone
compensation
0: Disabled
1: Enabled
11
ƾ
F5-38 Cooling fan control
0: Fan working during running
1: Fan working continuously
after power-on
10
ƿ
F5-39
([WHUQDOEUDNLQJ
startup frequency
+]WRPD[LPXP
IUHTXHQF\)
0.01 Hz 0.00 Hz
ƿ