Chapter 5 Function Parameter Table
-50-
Code Name Setup range
Minimum
unit
Factory
default
value
Cha-
nge
F5-11
Frequency upon
fault
-
0.01Hz 0.00Hz
*
F5-12 Current upon fault
-
0.01A 0.00A
*
F5-13
Bus voltage upon
fault
-
0.1V 0.0V
*
Group F6 Auxiliary Function
F6-00
maximum output
frequency
50.00Hz300.00Hz
0.01Hz 50.00Hz
×
F6-01
Frequency
upper limit
Frequency lower limit
maximum output frequency
0.01Hz 50.00Hz
ż
F6-02
Frequency lower
limit
0.00 - Frequency upper limit 0.01Hz 0.00Hz
ż
F6-03 Carrier frequency
0.5kHz 16.0kHz
0.1kHz
Model
dependent
ż
F6-04 Jog frequency
0.00Hz50.00Hz
0.01Hz 2.00Hz
ż
F6-05
Jog acceleration
time
0.0s 3000.0.0s
0.1
20.0s
ż
F6-06
Jog deceleration
time
0.0s3000.0.0s
0.1
20.0s
ż
F6-07 Reverse control
0: Reverse rotation enabled
1: Reverse rotation disabled
1 0 ż
F6-08
Forward/reverse
rotation
dead-zone time
0.0s 3000.0s
0.1s 0.0s
ż
F6-09
Start protection
function
0: Protection
1: No Protection
1 0 ż
F6-10
Frequency arrival
detection width
0.0% 100.0% (maximum
output frequency)
0.1% 0.0% ż