Chapter 5 Function Parameter Table 
 
-49- 
 
Code  Name Setup range 
Minimum
unit
Factory 
default 
value
Cha-
nge 
F5-10  Fault record type 
0: No fault 
1: Inverter unit    protection 
(ERR01) 
2: Acceleration over current 
(ERR02) 
3: Deceleration over current 
(ERR03) 
4: Constant speed over current 
(ERR04) 
5: Acceleration over 
voltage(ERR05) 
6: Deceleration over 
voltage(ERR06) 
7: Constant speed over 
voltage(ERR07) 
8: Control power supply 
fault(ERR08) 
9: Under voltage failure 
(ERR09) 
10: Inverter overload (ERR10) 
11: Motor overload (ERR11) 
12: Input phase loss (ERR12) 
13: Output phase loss (ERR13)
14: Heatsink over heat(ERR14)
15External fault(ERR15) 
16: Reserved 
17: Reserved 
18: Current detection 
fault(ERR18) 
19: Motor tuning fault (ERR19)
20: Reserved 
21EEPROM˄ERR21˅ 
22: Inverter hardware 
fault(ERR22) 
23: Motor to earth short circuit 
fault(ERR23)   
24: Reserved 
-  0  * 
 