Chapter 6 Parameter Description
-56-
F0-09
DI1
terminal
function
selection
Factory
default
value
1
(Forward
rotation)
F0-10
DI2
terminal
function
selection
Factory
default
value
4
(Forward
rotation
Jog)
F0-11
DI3
terminal
function
selection
Factory
default
value
12 (MS
speed 1)
F0-12
DI4
terminal
function
selection
Factory
default
value
13 (MS
speed 2)
This parameter is used to set the functions of
the multifunctional digital input terminals. If the
input selects PULSE, all DI4 functions are
disabled, and the input can only corresponds
to PULSE.
Set up
Function Description
0
No
function
Even when there is
signal input, the inverter
still has no action. The
no operation function
can be set on the
unused terminals so as
to prevent error action.
1
Forward
rotation
(FWD)
2
Reverse
rotation
Control the forward
rotation and reverse
rotation of the inverter
via the external
terminals.
Set up
Function Description
(REV)
3
Three-line
mode
running
control
This terminal is used to
confirm that the inverter
running mode is
three-line control mode
For detailed description,
please refer to F3-00
three-line control mode
function code.
4
Forward
rotation
Jog
(FJOG)
5
Reverse
rotation
Jog
(RJOG)
FJOG refers to Jog
forward rotation, while
RJOG refers to Jog
reverse rotation. For
details regarding
frequency and Jog
acceleration/deceleratio
n time during the Jog
running, refer to F6-04,
F6-05 and F6-06
function codes.
6
Terminal
UP
7
Terminal
DOWN
When the frequency is
given by the external
terminals, it is used as
gain and decrement
commands of frequency
modification. When the
frequency source is set
to digital setup, it can be
used to adjust the setup
frequency.
8
Coast to
stop
The inverter locks the
output, and the motor
stop process is beyond