Chapter 6 Parameter Description
-58-
Frequen
cy Setup
Corresp
onding
Paramet
er
OFF OFF
MS
speed 0
MS
speed 0
OFF ON
MS
speed 1
MS
speed 1
ON OFF
MS
speed 2
MS
speed 2
ON ON
MS
speed 3
MS
speed 3
DO output
selection
(collector
open
output
terminal)
Factory
default
value
1:
Inverte
r is
runnin
g
F0-13
Setup range
03
Set up
value
Function Description
0
no output
The output terminals
does not have any
function.
1
Inverter is
running
It indicates the
inverter is running,
and there is output
frequency, and ON
signal will output at
this time.
2
Fault
output
When the inverter is
faulty, it outputs ON
signal.
3
Frequency
arrival
Please refer to F6-10
for details.
output
selection
(Analog
output
terminal
Factory
default
value
0
F0-14
Setup range
05
The standard for analog output is from 0mA to
20mA (or from 0V to 10V).
The corresponding value range that it
indicates is shown in the table below:
Set up
value
Function Description
0
running
frequency
0 to maximum
output frequency
1
Setup
frequency
0 to maximum
output frequency
2
Output
current
0-2 times of
inverter rated
current
3
PULSE
input
0.1kHz50.0kHz
4 AI1
0V10V
5
AI2
0V 10V/0mA
20mA
Start
mode
Factory
default
value
0
0 Direct startup
F0-15
Setup
range
1
Rotation speed
tracking restart
0: Direct start
Start up with the start frequency.