MD380 User Manual Function Code Table
- 121 -
)unction
Code
Parameter Name
Setting Range
Default Property
A2-61 Motor 2 control mode
6HQVRUOHVVÀX[YHFWRUFRQWURO
6)9&
1: Closed-loop vector control
(CLVC)
9ROWDJH)UHTXHQF\9)
control
0 ƿ
A2-62
Motor 2 acceleration/
deceleration time
0: Same as motor 1
1: Acceleration/Deceleration time 1
2: Acceleration/Deceleration time 2
3: Acceleration/Deceleration time 3
4: Acceleration/Deceleration time 4
0 ƿ
A2-63 Motor 2 torque boost
0.0%: Automatic torque boost
0.1%–30.0%
Model
dependent
ƿ
A2-65
Motor 2 oscillation
suppression gain
0–100
Model
dependent
ƿ
Group A
3: Motor 3 Parameters
A3-00 Motor type selection
0: Common asynchronous motor
1: Variable frequency
asynchronous motor
2: Permanent magnetic
synchronous motor
0 ƾ
A3-01 Rated motor power
0.1–1000.0 kW
Model
dependent
ƾ
A3-02 Rated motor voltage
1–2000 V
Model
dependent
ƾ
A3-03 Rated motor current
±$$&GULYHSRZHU
55 kW)
±$$&GULYHSRZHU!
55 kW)
Model
dependent
ƾ
A3-04 Rated motor frequency
0.01 Hz to maximum frequency
Model
dependent
ƾ
A3-05
Rated motor rotational
speed
1–65535 RPM
Model
dependent
ƾ
A3-06
Stator resistance
(asynchronous motor)
±$&GULYHSRZHU
N:
±$&GULYH
SRZHU!N:
Model
dependent
ƾ
A3-07
Rotor resistance
(asynchronous motor)
±$&GULYHSRZHU
N:
±$&GULYH
SRZHU!N:
Model
dependent
ƾ
efesotomasyon.com