MD380 User Manual Desc
ription of Function Codes
- 177 -
,WLVXVHGWRVHWWKHORJLFRIRXWSXWWHUPLQDOV)05UHOD\UHOD\'2DQG'2
0: Positive logic
The output terminal is valid when being connected with COM, and invalid when being
disconnected from COM.
1: Positive logic
The output terminal is invalid when being connected with COM, and valid when being
disconnected from COM.
Group )6: Start/Stop Control
)unction Code Parameter Name Setting Range Default
)6-00 Start mode
0: Direct start
1: Rotational speed tracking restart
2: Pre-excited start (asynchronous motor)
0
0: Direct start
–
If the DC braking time is set to 0, the AC drive starts to run at the startup
frequency.
–
If the DC braking time is not 0, the AC drive performs DC braking first and
then starts to run at the startup frequency. It is applicable to small-inertia load
application where the motor is likely to rotate at startup.
1: Rotational speed tracking restart
7KH$&GULYHMXGJHVWKHURWDWLRQDOVSHHGDQGGLUHFWLRQRIWKHPRWRU¿UVWDQGWKHQVWDUWV
at the tracked frequency. Such smooth start has no impact on the rotating motor. It
is applicable to the restart upon instantaneous power failure of large-inertia load. To
ensure the performance of rotational speed tracking restart, set the motor parameters
LQJURXS)FRUUHFWO\
2: Pre-excited start (asynchronous motor)
,WLVYDOLGRQO\IRUDV\QFKURQRXVPRWRUDQGXVHGIRUEXLOGLQJWKHPDJQHWLF¿HOGEHIRUH
WKHPRWRUUXQV)RUSUHH[FLWHGFXUUHQWDQGSUHH[FLWHGWLPHVHHSDUDPHWHUVRI)
DQG)
–
If the pre-excited time is 0, the AC drive cancels pre-excitation and starts to run at
startup frequency.
–
If the pre-excited time is not 0, the AC drive pre-excites first before startup,
improving the dynamic response of the motor.
)unction Code Parameter Name Setting Range Default
)6-01
Rotational speed
tracking mode
0: )rom frequency at stop
1: )rom zero speed
2: )rom maximum frequency
0
To complete the rotational speed tracking process within the shortest time, select the proper
mode in which the AC drive tracks the motor rotational speed.