MD380 User Manual Desc
ription of Function Codes
- 145 -
)LJXUH$FFHOHUDWLRQ'HFHOHUDWLRQWLPH
Time (t)
Output frequency
(Hz)
Set frequency
Acceleration/Deceleration
base frequency
t1
t2
Set deceleration time
Actual acceleration time
Actual deceleration time
Set acceleration time
The MD380 provides totally four groups of acceleration/deceleration time for selection. You
can perform switchover by using a DI terminal.
 *URXS))
 *URXS))
 *URXS))
 *URXS))
)unction Code Parameter Name Setting Range Default
)0-19 Acceleration/Deceleration time unit
0:1s
1: 0.1s
2: 0.01s
1
To satisfy requirements of different applications, the MD380 provides three acceleration/
deceleration time units, 1s, 0.1s and 0.01s.
Note
Modifying this parameter will make the displayed decimal places change and corresponding
acceleration/deceleration time also change.
)unction Code Parameter Name Setting Range Default
)0-21
)requency offset of auxiliary frequency
source for X and Y operation
0.00 Hz to maximum
frequency ()0-10)
0.00 Hz
This parameter is valid only when the frequency source is set to "X and Y operation". The
¿QDOIUHTXHQF\LVREWDLQHGE\DGGLQJWKHIUHTXHQF\RIIVHWVHWLQWKLVSDUDPHWHUWRWKH;DQG
Y operation result.